300KW-DC450V programmable DC test load bank
300KW-DC450V programmable DC test load bank
RELIABLE BY DESIGN
300KW-DC450V programmable DC test load bank
Brand: INLANX
Description: The INLANX-300KW-DC450V programmable DC test load bank uses purely resistive load elements, supports local touchscreen control and RS485 remote communication, and is intended for testing DC power supplies, energy storage and DC distribution equipment.
Resistance, power rating, tolerance, TCR, package, lead length, mounting method, and labeling and packaging can all be customized.
Product series across the site can serve as alternatives to EBG, HVR, Vishay and other brands. Customers must verify samples and specifications before using replacement models in volume.
- Size
- 1400*1900*900 mm
- Rated power
- 300KW
- Tolerance
- ±10%
- TCR
- 400ppm℃
- Technology
- Cabinet-type programmable DC resistive load
- Series
- 300KW-DC450V programmable DC test load bank
- Brand
- INLANX
- Mounting
- Indoor floor-standing; forced-air cooling
Product details
Product description
300kW-DC450V DC programmable test load bank is a highly reliable programmable load device developed for testing DC power systems, energy storage systems, rectifier power supplies, DC power distribution equipment and related electrical systems. It uses highly stable purely resistive load units and combines power steps for multilevel loading, suitable for factory testing, type testing, aging tests, on-site commissioning and research verification. The device supports local touchscreen and remote communication control, monitors and displays operating voltage, current and power in real time, and provides overtemperature, overcurrent and short-circuit protection. It supports extended continuous operation and stable loaded operation in industrial test environments.
Technical features
- 1. Stepped loading: Multilevel power steps can be combined through switching signals or the control system. The minimum adjustment step is 10kW, meeting DC load-testing requirements under various operating conditions.
- 2. Rapid switching: Supports rapid switching at 25%, 50%, 75%, 100% and preset power levels for step loading, dynamic response testing and verification of switching under load.
- 3. Local control: The local interface supports start, stop, step switching, parameter setting and operating-status viewing.
- 4. Remote communication: An RS485 interface connects to a host computer, PLC or centralized monitoring system for remote parameter reading, status monitoring and load control.
- 5. Parameter monitoring: Monitors DC voltage, current, power and internal temperature during operation for test recording and operational analysis.
- 1. Overtemperature protection: Internal temperature sensors monitor cabinet temperature in real time. When the internal temperature exceeds the set safe value, the system automatically disconnects the load and issues an alarm.
- 2. Fan interlock protection: Loading is inhibited until the fan power switch is turned on, preventing accidental loading without cooling.
- 3. Abnormal shutdown protection: Automatically unloads when abnormal operation occurs to ensure safe system operation.
- 4. Emergency-stop protection: An optional emergency-stop button quickly disconnects the load output in an emergency.
- 5. Short-circuit protection
- 6. Overcurrent protection
Technical specifications
| Product name | Cabinet-type DC purely resistive programmable load equipment |
|---|---|
| Model | INLANX-300KW-DC450V |
| Rated power | 300KW at DC450V |
| Power steps (tentative) | 10KW, 10KW, 20KW, 20KW, 8 × 30KW |
| Minimum step | 10KW |
| Rapid switching | 25%, 50%, 75%, 100% and preset power |
| Load resistance accuracy | ± 1% |
| Control method | Local touchscreen, RS485 remote control |
| Parameter monitoring | DC voltage, current, power and internal cabinet temperature |
| Control supply | 220V; internal supply available |
| Load terminals | Connect 4 sets of 95 mm ² cables; reserve connection busbars |
| Insulation class | Class F |
| Cooling method | Forced-air cooling |
| Cabinet dimensions | Width 1400 × height 1900 × depth 900 mm |
| Weight | 450 kg |
| Protection functions | Overtemperature, fan interlock, abnormal shutdown, short circuit, overcurrent; optional emergency stop |
| Operating environment | − 10 ℃~ 40 ℃, relative humidity ≤ 95%RH |
Applications and selection
- Load testing of DC power systems; performance verification on the DC side of energy storage systems.
- Output testing of rectifier power supplies and charging equipment; factory testing of DC supply cabinets and power distribution systems.
- Aging and continuous-operation testing of electrical products; construction of test platforms for research institutes, laboratories and production workshops.