80KW-AC380V AC resistance load bank
80KW-AC380V AC resistance load bank
RELIABLE BY DESIGN
80KW-AC380V AC resistance load bank
Brand: INLANX
Description: INLANX-80KW-AC380V 80KW AC resistance load bank is made of nickel-chromium alloy material, which is characterized by very small temperature drift, high melting point and corrosion resistance. When used as a load, the power is stable and fully meets the test requirements. It is mainly used as a simulated load when testing the load capacity and other electrical performance of the generator or UPS.
Resistance, power rating, tolerance, TCR, package, lead length, mounting method, and labeling and packaging can all be customized.
Product series across the site can serve as alternatives to EBG, HVR, Vishay and other brands. Customers must verify samples and specifications before using replacement models in volume.
- Size
- 650*1300*850 mm
- Rated power
- 80KW
- Tolerance
- ±10%
- TCR
- 400ppm℃
- Technology
- Nickel-chromium alloy
- Series
- 80KW-AC380V AC resistance load bank
- Brand
- INLANX
Product details
Product description
Our high-power AC load bank serves as a simulated load for testing generator or UPS load capacity and other electrical performance.
Technical features
- The load bank uses nickel-chromium alloy resistors with very low temperature drift, a high melting point and corrosion resistance. They provide stable load power to meet testing needs and are widely used domestically and internationally as load and heating materials.
- Internal wiring uses high-temperature silicone cable rated above 120℃, which does not burn at high temperatures. The protection temperature is set to 70℃. A fan interlock prevents loading when the fan is off. Excessive temperature disconnects load power and triggers audible and visual alarms.
- The load bank provides comprehensive protection and contains multiple resistor modules. Different load powers can be selected for different test objects to evaluate their electrical performance.
Technical specifications
| Rated voltage | AC380V |
|---|---|
| Rated power | 80KW |
| Power stages (three-phase AC) | 1KW,2KW,2KW,5KW,10KW,15KW,15KW,30KW |
| Power factor | 1 |
| Load accuracy | ≤ 5% |
| Fan supply | AC220V |
| Load connection | Quick connectors |
| Enclosure dimensions | W*H*D=650*1300*850 |
| Operating ambient temperature | Below 70 degrees (set protection temperature) |
| Cooling | Forced air cooling (front intake, rear exhaust) |
Applications and selection
- As a simulated load, test load capacity and wiring reliability throughout the electrical chain from substation/distribution equipment and diesel generators to UPS, row distribution cabinets and PDU.
- As a simulated load, check whether precision air conditioning meets requirements as aisle or equipment-room temperature rises.
- As a simulated load, test UPS transfer capability under load and power-supply duration.
- As a simulated load, test whether diesel generators can start and supply power normally under load.
- Other simulated-load tests.