ENS-3805C Battery Charger
ENS-3805C Battery Charger
RELIABLE BY DESIGN
ENS-3805C Battery Charger
Brand: INLANX
Description: ENS-3805C Battery Charger. Please refer to the uploaded datasheet for detailed technical specifications and operating conditions.
Resistance, power rating, tolerance, TCR, package, lead length, mounting method, and labeling and packaging can all be customized.
Product series across the site can serve as alternatives to EBG, HVR, Vishay and other brands. Customers must verify samples and specifications before using replacement models in volume.
- Size
- 500*260*275mm
- Tolerance
- ±0.5% / ±0.1% / ±1%
- Technology
- PTC
- Series
- ENS-3805C Battery Charger
- Brand
- INLANX
Product details
Product description
Uses three-stage charging with constant current, constant voltage with tapering current, and trickle/float charging. Records voltage, current, time and capacity, and supports data export and PC analysis.
Technical features
- Three-stage charging: constant current → constant voltage with tapering current (equalization voltage regulation) → trickle/float charging; automatically controls charging for lead-acid batteries, lithium batteries and UPS power-supply maintenance.
- Automatic termination: stops charging when battery-group terminal voltage or cell voltage reaches its configured upper limit, charging time reaches its configured value, or charging capacity reaches its configured value; records continuous process data.
- Touch operation: 7-inch high-brightness TFT LCD with a resistive touchscreen, 1024×600 resolution and direct on-screen operation.
- Wireless cell monitoring (optional): LoRa modules support 2V, 4V, 6V and 12V cells; each module monitors 6 cells simultaneously. The source example is a 48V battery group using 4 modules.
- Wireless bands: receives and modifies the bands of wireless cell-monitoring modules and supports 1-10 band settings for multiple instruments in the same equipment room.
- Cell analysis: when fitted with cell acquisition modules, displays charging cell voltages in real time as bar charts and data tables, and identifies the highest- and lowest-voltage cells.
- Historical curves: allows review of recorded battery-group voltage and current curves.
- Charging templates: 6 built-in test templates can be edited and recalled.
- Data management: supports USB-drive data transfer, PC software analysis and report generation; test-data names can be edited on the main unit.
- Power-loss recovery: enabled by default. Automatically resumes the test state from before the power interruption when mains power returns, maintaining continuous test records.
- Online monitoring (optional): requires cell modules and a current clamp; monitors and records battery-group voltage, current, capacity and time, and can generate reports.
- Reserved interfaces: RS485 master interface for cell-voltage acquisition, RS485 slave interface for remote control, and CAN interface for reading signal inputs. Actual interface enablement follows the technical specifications.
Technical specifications
| Charge voltage | 90-450 VDC |
|---|---|
| Dimensions (length × width × height) | 500 × 260 × 275 mm |
| Main-unit mass | ≤15 kg |
| AC supply | AC 380 V (ABCN+PE), 40-60 Hz |
| Operation | Touchscreen |
| Display | 7-inch TFT LCD, resistive touch, 1024×600 |
| Data communication | RS485×1 (disabled by default) |
| Internal storage | 8 Gbit FLASH |
| Voltage measurement accuracy | ±0.5%FS + 0.1 V |
| Current measurement accuracy | ±1%FS + 0.1 A |
| Group voltage display accuracy | 0.1 V |
| Group current display accuracy | 0.01 A |
| Main-unit protection | Shutdown on overtemperature, overcurrent or loss of current control |
| Shutdown device | High-voltage DC switch |
| Reverse-polarity protection | Supported |
| Abnormal-condition protection | Power loss at the power cable or main cable |
| Overtemperature thresholds | Resistor enclosure 85°C; heatsink 100°C |
| Alarm indication | LCD indication and buzzer |
| Cooling | Forced-air cooling |
| Operating temperature | -5 to +50°C |
| Storage temperature | -40 to +70°C |
| Relative humidity | 0-90% RH (40±2°C) |
| Rated altitude | 2000 m |
Applications and selection