RSL Water-Cooled High-Frequency Power Resistor
RSL Water-Cooled High-Frequency Power Resistor
RELIABLE BY DESIGN
RSL Water-Cooled High-Frequency Power Resistor
Brand: INLANX
Description: The RSL water-cooled high-frequency power resistor uses a full-coverage metal oxide film on a ceramic rod with an Al2O3 content greater than 95%. It is compact, offers good overload capability, low inductance, and excellent high-frequency performance, and can be used in a wide range of high-frequency circuits. Special specifications can be customized by agreement. Vertical installation is required. The resistor has a water inlet and outlet. Cooling-water flow must be at least 1 L/min for every 1 kW of power dissipated; operation at 5 kW requires at least 5 L/min. In a recirculating water-cooling system, the cooling water must be cooled before reuse.
Resistance, power rating, tolerance, TCR, package, lead length, mounting method, and labeling and packaging can all be customized.
Product series across the site can serve as alternatives to EBG, HVR, Vishay and other brands. Customers must verify samples and specifications before using replacement models in volume.
- Resistance
- 5 Ω – 1 kΩ
- Size
- 46*182 mm
- Rated power
- 5000 W
- Tolerance
- ±5% / ±10%
- TCR
- ±100–±400 ppm/℃
- Series
- RSL Water-Cooled High-Frequency Power Resistor
- Brand
- INLANX
Product details
Product description
RSL water-cooled high-frequency power resistor
Technical features
- Small size, good overload performance, low inductance and excellent high-frequency performance; suitable for widespread use in high-frequency circuits. Special specifications can becustomized by agreement.
Model table
| Model | Rated power(W) | Resistance range(Ω) | Resistance tolerance | Temperature coefficient(ppm/°C) | D × L(mm) |
|---|---|---|---|---|---|
| RSL-I | 5000 | 5~1000 | ±5%~±10% | ±100~±400 | 46 × (182±1) |
Technical specifications
| Resistive film | Metal oxide film, full coverage |
|---|---|
| Core | Ceramic rod, Al2O3 content >95% |
| Technical standards | GJB3017-97 · QJB/QH1619-2007 |
| Instructions | 1. Only vertical mounting is permitted; provide a water inlet and outlet. |
| Instructions | 2. For each 1 kW of power dissipated, cooling-water flow must be at least 1 L/min. |
| Instructions | 3. Source derated-use example: 5 kW ≥5 L/min. |
| Instructions | 4. Cool the cooling water in the recirculating water-cooling system before reuse; specifications outside the above range can be customized by agreement. |
| Instructions | Note: the source does not specify the inlet and outlet directions; the general cooling-flow requirement and the rated example are retained as stated in the source. |
Applications and selection
- Suitable for widespread use in high-frequency circuits.