120KW-AC380V-R

Brand: INLANX

Description: INLANX-120KW-AC380V-R high-power AC load bank uses nickel-chromium alloy resistors, panel manual step loading and forced air cooling, which is suitable for power system load testing. Used to test the load capacity and other electrical performance of generators and UPS, providing a 120KW AC simulated load.

Resistance, power rating, tolerance, TCR, package, lead length, mounting method, and labeling and packaging can all be customized.

Product series across the site can serve as alternatives to EBG, HVR, Vishay and other brands. Customers must verify samples and specifications before using replacement models in volume.

Total stock: 100

Size
650*1800*850 mm
Rated power
120000 W
Tolerance
±10%
TCR
400 ppm
Technology
Nickel-chromium alloy
Series
120KW-AC380V-R high power AC load bank
Brand
INLANX

Description: INLANX-120KW-AC380V-R high-power AC load bank uses nickel-chromium alloy resistors, panel manual step loading and forced air cooling, which is suitable for power system load testing. Used to test the load capacity and other electrical performance of generators and UPS, providing a 120KW AC simulated load.

Total stock: 100

Brand: INLANX

Product details

Product description

Provides a 120KW simulated AC load to test generator and UPS load capacity and other electrical performance.

Technical features

  • Nickel-chromium alloy resistors provide stable power; internal high-temperature silicone cables withstand temperatures above 120℃.
  • Panel 1P switches manually select and combine power steps.

Model table

Model
INLANX-120KW-AC380V-R

Technical specifications

ProductHigh-power AC load bank
Rated voltageAC380V
Rated power120KW
Three-phase AC load steps3KW、6KW、6KW、15KW、3×30KW
Single-phase AC load steps1KW、2KW、2KW、5KW、10KW、10KW、10KW
Power factor1
Load accuracy≤5%
Fan / control supplyAC220V
Load connectionQuick connector
Cabinet dimensionsWidth 650 × height 1800 × depth 850 mm
Operating temperatureBelow 70℃ (set protection temperature)
CoolingForced air, front intake / rear exhaust
Loading methodManual control-panel switching (1P switches)
Resistor materialNickel-chromium alloy
Temperature protection70℃ protection setting; audible and visual alarm on overheating
Operation notesStart the fan before applying load. After unloading, continue running the fan for about 3 minutes; disconnect the source side before the load side.

Applications and selection

  • • Test the load capacity of distribution equipment, diesel generators, UPS, row distribution cabinets and PDU electrical chains.
  • • Check UPS load transfer and supply duration, diesel generator starting under load and computer-room air-conditioning operation.