INLANX
Nederlands

Geen klantenaccount nodig. Gebruik gastformulieren voor vragen en sample-aanvragen.

Inzichten

HV Pulse Protection and Kelvin Current Sensing

Design resistor networks for solar, ESS and HVDC systems by checking pulse energy, voltage stress, creepage, TCR and Kelvin sensing error.

Separate Voltage, Energy and Measurement Requirements

Solar inverters, energy storage systems (ESS) and HVDC equipment often need high-value resistors for sensing or discharge and very low-value shunts for current measurement. The two functions may share a DC bus but fail for different reasons. The voltage path must withstand continuous stress, transients and insulation demands. The current path must control self-heating and millivolt-level measurement error. A design review should therefore keep continuous voltage, surge energy, thermal conditions and sensing accuracy as separate checks.

For a divider, the total resistance sets current and total dissipation, while the ratio sets the sensed voltage. Calculate voltage and power in each element at the highest credible bus voltage and resistance-tolerance extremes. Check each resistor's continuous working-voltage limit separately from its wattage. For a simple DC-link discharge, stored capacitor energy is E = ½CV², and the ideal RC time constant describes the decay. In a real circuit, switches, parallel paths and active loads determine how much of that energy reaches any one resistor.

Solar and ESS DC-link schematic with voltage divider, discharge resistor and current-sense shunt.
Solar and ESS DC-link schematic with voltage divider, discharge resistor and current-sense shunt.

Check Pulse Withstand Against the Actual Waveform

Startup, load rejection and protective switching can impose short voltage or current peaks that exceed the normal bus condition. Record peak magnitude, duration, rise time, repetition rate and the allowed resistance shift after stress. A continuous-power rating cannot replace a pulse-load curve. Likewise, a single successful surge test does not prove suitability for a long sequence of similar events: incomplete cooling between pulses can raise the next pulse's starting temperature.

INLANX's RI80 high-voltage glass-glaze series is a candidate for divider, load and discharge functions. Its published technical guidance explains how to review construction, resistance, power, working voltage, divider error and pulse energy separately. Select a specific model only after matching those limits to the circuit waveform and mounting environment. For a series-connected divider, check unequal voltage sharing caused by tolerance and temperature coefficient of resistance (TCR), particularly when elements operate at different temperatures.

INLANX RI80 high-voltage glass-glaze resistor product range for divider and discharge applications.
INLANX RI80 high-voltage glass-glaze resistor product range for divider and discharge applications.

Make PCB Insulation Part of the Calculation

A high-voltage-rated resistor does not make the assembled PCB high-voltage-rated. Creepage follows an insulating surface; clearance is the shortest route through air. Review both around terminals, mounting hardware, board slots and neighboring low-voltage circuitry. The required distances depend on the applicable equipment standard, working voltage, material properties, pollution degree and installation conditions. There is no universal spacing number suitable for every solar or HVDC cabinet.

Static divider accuracy is also different from transient response. Resistor parasitic capacitance, board capacitance and leakage can produce momentary unequal sharing or measurement error during a fast edge. If the voltage signal is used for protection, characterize the installed divider and filter as a complete network rather than assuming its DC ratio applies at every frequency.

Conceptual high-voltage PCB layout showing creepage, clearance and an isolation slot.
Conceptual high-voltage PCB layout showing creepage, clearance and an isolation slot.

Use Kelvin Sensing, Then Budget the Remaining Error

An ideal shunt produces V_sense = I × R_shunt. In practice, copper traces, bolted joints and power terminals can add voltage drops comparable to the signal being measured. Four-terminal Kelvin sensing uses separate high-current and voltage-sense paths so the amplifier measures closer to the resistive element. Route the sense pair together, away from switching loops, and verify amplifier common-mode range, input offset, filtering and isolation.

Four-terminal Kelvin current-sense shunt wiring with separate force and sense connections.
Four-terminal Kelvin current-sense shunt wiring with separate force and sense connections.

As an example, a 100 µΩ shunt carrying 200 A produces 20 mV and dissipates 4 W. Those are nominal calculations, not a complete accuracy claim. The INLANX HSM-350 data lists 100 µΩ with an initial resistance tolerance of ±5%, so calibration or system-level compensation may be necessary if the application requires precise current readings. Self-heating and TCR then change resistance further. The exact HSM model, connector pinout, rated current and thermal limits must be checked from its datasheet before layout release.

INLANX HSM shunt current sensor module; verify model-specific pinout and tolerance.
INLANX HSM shunt current sensor module; verify model-specific pinout and tolerance.
Selection checkHigh-voltage resistor pathCurrent-sense shunt path
Main stressContinuous voltage and surge energyContinuous current and fault energy
Accuracy concernDivider ratio, leakage and TCRKelvin pickup, tolerance, TCR and amplifier error
Layout priorityCreepage, clearance and isolationShort, symmetric sense connections
ValidationMaximum bus voltage and surge sequenceCurrent cycling and measured sense error

Validate the Combined System

Capture maximum bus voltage, surge waveform, shunt current and temperature during startup, normal conversion and protective shutdown. Recheck divider ratio and current-measurement error after thermal cycling and surge tests. Record the actual PCB spacing and insulation conditions used in the qualification build. These measurements reveal whether a part that looks suitable on a component table remains suitable in the assembled system.

For a model review, send INLANX the voltage range, capacitor energy, surge waveform, current profile, accuracy target and layout constraints. The engineering team can then compare an RI80 configuration with an HSM shunt solution, provide datasheets and samples, and discuss custom specifications where standard options do not fit. Prototype validation remains the final step before production release.

Neem contact met ons op om uw eisen te bespreken

Of u nu een standaardweerstand nodig hebt of een maatwerkoplossing voor een gespecialiseerde industriële toepassing, ons team helpt u graag. Neem contact op voor uitgebreid advies, technisch overleg of een fabrieksbezoek.